Displayed parameters
Transponder type
Antenna status
Presence check
Table 7- 20
Displayed parameters
UID
Transponder type
Version
Lock status of the OTP
area
Size of the user
memory
Size of a memory block Size of the memory blocks of the transponder chip
Number of memory
blocks
Measured value power
flux density
Passive error counter
Active error counter
Presence counter
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
Description
Set transponder type profile
The following values are possible:
Value
00
01
03
04
05
06
07
08
10
20
31
40
41
50
4F
Status of the antenna
Set presence check profile
Displayed parameters of the "Transponder status" area
Description
Unique identifier of the transponder
Transponder type (vendor, identification)
Version of the transponder chip
Disabled blocks of the OTP area on the chip
Memory size of the user memory in bytes
Number of memory blocks of the transponder chip
Radiant power that arrives at the transponder.
The lower the value, the more power the transponder receives.
Number of passive errors which occurred
Number of errors which occurred
Sum of the signature and CRC errors
Time in [ms] that the transponder spent in the antenna field.
Meaning
RF300 (RF3xxT)
ISO 15693 general
MDS D3xx, Infineon
MDS D4xx, Fujitsu - 2 KB
MDS D1xx, NXP
MDS D2xx, TI
MDS D261, ISTM
MDS D5xx, Fujitsu - 8 KB
RF300 (RF3xxT)
ISO 14443 (MOBY E, E6xx)
General Mode
P2P master
P2P master & combined mode with ISO transponder (MDS
Dxxx)
P2P master & combined mode with RF300 transponder
P2P slave
Configuring with the WBM
7.3 The menu items of the WBM