Siemens SIMATIC RF185C Operating Instructions Manual page 74

Hide thumbs Also See for SIMATIC RF185C:
Table of Contents

Advertisement

Configuring with the WBM
7.3 The menu items of the WBM
If you have set another parameter value in the "Ident devices/system" parameter and
depending on the basic parameters set, you can configure the following reader parameters
in the "Reader parameters" parameter group.
Table 7- 6
Parameters in the "Reader parameters" parameter group I
Parameter
Presence check
RF power
1)
Reset error LED
Max. number of tran-
sponders
Reader mode
ECC mode
Transponder type
You can find a detailed description of these parameters in the following paragraphs.
1)
74
Parameter value
On
Off (RF field on)
Off (RF field off)
0.50 ... 5.00
On
Off
1 ... 40
Normal operation
P2P master
P2P master + ISO
P2P master + RF300
P2P slave
On
Off
1)
Default value
Description
On
1.00
Setting for the output power of the reader.
1.25
Off
1
Number of transponders expected in the anten-
na field.
Normal operation
Selection of the required reader mode. This
parameter is intended for trained users. As a
rule, the "Normal operation" operating mode of
the reader is used.
For P2P mode, one reader must be configured
as a "P2P slave" and one reader as a "P2P
master". If the P2P master also communicates
with ISO or RF300 transponders, you must
select the appropriate parameter value.
Off
Switching the ECC mode on/off
In ECC mode, the reader can detect bit errors
on the transponder with a high degree of prob-
ability and correct the sent data, if possible.
Selection of the transponder types used.
1)
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
On
Presence is reported as soon as there is a
transponder in the antenna field of the read-
er.
Off (RF field on)
The presence check on the FB is sup-
pressed. The antenna on the reader is nev-
ertheless turned on as long as it has not
been turned off by a command.
Off (RF field off)
The antenna is turned on only when a
command is sent and it then turns itself off
again.
On
The flashing of the error LED on the reader
is reset by each reset and by a new OPC
command.
Off
The error LED always indicates the last er-
ror. The display can only be reset by turning
off the reader.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents