7.3 The menu items of the WBM
Error counter
The following error types are read and displayed:
Table 7- 21
Displayed error types
FZP
ABZ
CFZ
SFZ
CRCFZ
ASMFZ
Signal strength
AMLI
PMLI
Note
Error counter readings
The displayed error counter readings are counted from the last restart of the reader or the
last manual reset of the error counter readings.
96
Error types displayed in the "Error counter" area
Description
Passive error counter
This error counter is an indicator of a disturbed environment (interferences).
Abort counter
Counter for protocol errors on the air interface for which the transponder
aborted communication.
Code error counter
Counter for disruptions or collisions on the air interface that caused com-
munication to be disturbed.
Signature error counter
Counter for failed signature encryptions of written blocks of data. Only rele-
vant for the transponder type "RF300".
CRC error counter
Counter for failed CRC checks
Error counter for problems on the interface to the host (CM/PC)
Counter for errors on the serial interface
AM power indicator
Received signal strength [dB] for which amplitude modulation with the tran-
sponder was detected.
PM power indicator
Received signal strength [dB] for which phase modulation with the tran-
sponder was detected.