Connection
5.5 Connecting the communications module
Wiring interfaces/connectors
The following tables show the pin assignment for the interfaces/connectors.
Table 5- 2
Pin
Table 5- 3
Pin
42
Pin assignment PROFINET IO; M12 socket (4-pin, D-coded)
Assignment
1
Data line TxP
2
Data line RxP
3
Data line TxN
4
Data line RxN
Pin assignment power supply; M12 socket (4-pin, L-coded)
Assignment
1
L1: +24 V (brown)
2
N2: 0 V load supply (white)
Relevant for RF18xCI devices
3
N1: 0 V (blue)
4
L2: +24 V (black)
View of M12 socket, 4-pin
View of M12 socket, 4-pin