Service and maintenance
12.2 Error messages
"ER"
Block (hex)
LED
4x
0xE1FE0400
4x
0xE1FE0500
4x
0xE1FE0600
4x
0xE1FE0700
4x
0xE1FE0800
4x
0xE1FE0900
4x
0xE1FE0A00
4x
0xE1FE8100
4x
0xE1FE8200
4x
0xE1FE8300
4x
0xE1FE8400
4x
0xE1FE8500
156
Error description
Initialization error
Transponder is unable to execute the initialization command
Possible causes:
Transponder is defective.
The transponder memory is full.
Error in transponder memory
The transponder has never been written to or has lost the contents of its memory due to battery
failure.
Possible causes / action to be taken:
Replace the transponder (if the battery bit is set).
Re-initialize the transponder.
ECC error
The transponder in the antenna field does not have the expected UID / EPC ID or has no UID /
EPC ID.
The command is not supported by the transponder.
The transponder is read/write-protected.
The transponder is not responding.
The transponder password is incorrect. Access is denied.
The verification of the written transponder data has failed.
Possible causes:
Transponder is defective.
Transponder is in the limit area.
General transponder error
The transponder has too little power to execute the command.
Possible causes:
Transponder is in the limit area.
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI