Siemens SIMATIC RF185C Operating Instructions Manual page 157

Hide thumbs Also See for SIMATIC RF185C:
Table of Contents

Advertisement

"ER"
Block (hex)
LED
4x
0xE2FE0100
4x
0xE2FE0200
4x
0xE2FE8100
4x
0xE2FE8200
4x
0xE2FE8300
4x
0xE2FE8400
4x
0xE2FE8500
4x
0xE2FE8600
4x
0xE2FE8700
4x
0xE2FE8800
--
0xE3FE0100
--
0xE3FE0200
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
Error description
Field disturbance on reader
Possible causes:
The reader is receiving interference pulses from the environment.
External interference field. The interference field can be detected with the "inductive field
indicator" of the mobile reader.
The distance between two readers is too small and does not correspond to the configura-
tion guidelines.
The connecting cable to the reader is defective or too long or does not comply with the
specification.
Too many transmit errors
The transponder was unable to receive the command or write data from the communication
module correctly even after several attempts.
The transponder is positioned exactly in the limit area of the transmission window.
Data transmission to the transponder is being affected by external interference.
CRC sending error
The transponder reports CRC errors frequently (transponder is positioned in the limit area
of the reader; transponder and/or reader has a hardware defect).
Only during initialization: CRC error on receipt of acknowledgment from transponder (cause
as for field interference on the reader).
When formatting, the transponder must be in the transmission window of the reader, other-
wise a timeout error will occur, in other words:
The transponder is located exactly in the limit range of the transmission window.
The transponder is defective and consumes too much power.
The EEPROM transponder was incorrectly configured by "FORMAT".
RF600:
No ETSI channel is available.
An incorrect communication standard was selected in the "INIT" command.
The expert parameter is incorrect.
The performance check of the ETSI radio profile is faulty.
More transponders are located in the transmission window than can be processed at the same
time by the reader.
There is no transponder with the required EPC ID/UID in the transmission window or there is no
transponder at all in the antenna field.
The requested data is not available.
CRC error in reader-transponder communication.
The selected antenna is not enabled.
The selected frequency is not enabled.
The carrier signal is not activated.
There is more than one transponder in the transmission window.
General radio protocol error
The file name is not allowed.
The file does not exist.
Service and maintenance
12.2 Error messages
157