Configuring
6.2 Configuration via PROFINET IO
Parameter
Diagnostics
messages
IO mode
1)
This parameter is only included for CI communication modules.
1)
56
Parameter value
None
Hard errors
Hard/soft errors
Input
Output
IO-Link
Default value
Description
None
With this parameter, you determine the extent
to which the reader-related diagnostic interrupt
messages are to be reported.
Input
You use this parameter to specify the mode of
the I/O interface of the communication module:
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
None:
No alarms are generated.
Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
Hard/soft errors:
Critical hardware faults and errors occurring
when processing commands are reported
by the S7 diagnostics.
Input:
Single digital input
Output:
Single digital output
IO-Link:
Mode for connection of an IO-Link device
with digital inputs/outputs.