Programming via OPC UA
10.2 OPC UA variables
Table 10- 25 DigitalOutputs
Path
Data type
Access
Description
Possible values
134
Root/Objects/DeviceSet/Read_point_x/IOData/DigitalIOPorts/Digi
talOutputs
String
R/W
Supplies the states of the digital outputs of the communication
module and allows the states of the output to be set.
The number of actually existing physical digital outputs depends
on the communication module version being used, the operating
mode of the digital inputs/outputs and on the connected IO-Link
module.
00000000 ... 11111111
Binary characters (0, 1) per output, also "x" on setting for mask-
ing out
Each position stands for an output of the communication module:
Outport00: 1st position (least significant bit right)
Outport01: 2nd position
Outport02: 3rd position
Outport03: 4th position
Outport04: 5th position
Outport05: 6th position
Outport06: 7th position
Outport07: 8th position
Read: Depending on the value of the particular position, the
corresponding output is at "ON" (1) or "OFF" (0).
Write: Depending on the value of the particular position, the cor-
responding output is set to "ON" (1) or "OFF" (0). Outputs whose
state is to remain unchanged can be masked out with "x".
Example:
xxxxxx01
Outport01 is switched off, Outport00 is switched on, the other
outputs remain unchanged.
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03