Siemens SIMATIC RF185C Operating Instructions Manual page 165

Hide thumbs Also See for SIMATIC RF185C:
Table of Contents

Advertisement

AutoId
OPC UA
status
status
18
good
19
good
19
good
19
good
19
good
19
good
19
good
19
good
19
good
20
good
20
good
--
--
--
OpcUa_
BadInva-
lidState
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
AutoId
text
INVALID_
CONFIGURATION
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
DEVICE_FAULT
DEVICE_FAULT
--
--
Error description
The specified tag field of the transponder is unknown.
The transponder is not responding.
The verification of the written transponder data has failed.
General transponder error
The transponder has too little power to execute the command.
The transponder signals a CRC error.
The selected frequency is not enabled.
The carrier signal is not activated.
General radio protocol error
Fault in power supply
The power supply is very close to the low limit.
Antenna errors
The antenna or the antenna cable is defective.
Error in the connection to the reader; the reader is not an-
swering (in PROFIBUS operation).
The cable between the communication module and
reader is wired incorrectly or there is a cable break
The 24 V supply voltage is not connected or is turned off
or has failed briefly
Automatic fuse on the communication module has blown
Hardware defective
Another reader is in the vicinity and is active
There is a reflecting metal surface in the vicinity that is
disrupting the antenna field
Execute "init_run" after correcting the error
The selected antenna is not enabled.
The command is not permitted in this status or is not supported.
Possible cause:
"INIT" was chained.
Command repetition was started without "Presence mode".
Service and maintenance
12.2 Error messages
165