Table 10- 19 PC
Path
Data type
Access
Description
Possible values
Table 10- 20 Polarization
Path
Data type
Access
Description
Possible values
Table 10- 21 Strength
Path
Data type
Access
Description
Possible values
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Rfid/PC
UInt16
R
Diagnostics on the last transponder access
Outputs the protocol control word of the transponder that was
accessed last. This variable is only supported by UHF readers.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Example:
3000
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Rfid/Polarization
String
R
Diagnostics on the last transponder access
Outputs the polarization with which the last command was exe-
cuted on the transponder. This variable is only supported by UHF
readers.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Default
Circular
Linear_vertical
Linear_horizontal
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Rfid/Strength
Int32
R
Diagnostics on the last transponder access
Outputs the RSSI value with which the last command was exe-
cuted on the transponder. This variable is only supported by UHF
readers.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
0 ... 255
Programming via OPC UA
10.2 OPC UA variables
131