Error Messages - Siemens SIMATIC Ident RF200 Operating Manual

Ascii protocol
Hide thumbs Also See for SIMATIC Ident RF200:
Table of Contents

Advertisement

2.11

Error messages

The following error messages are recognized by the RF200 system and entered in the
command acknowledgement in the "status" field.
Table 2- 19
Flashing of
red LED on
reader
00
02
05
06
12
13
19
20
21
24
25
28
30
--
ASCII protocol for RF200
Operating Manual, 11/2016, C79000-G8976-C329-04
Error codes of the RF200 readers
Error code
Description
0x00
no error
0x01
Presence error, possible causes:
The active command was not carried out completely
The transponder left the antenna field while the command was
being processed
Communication problem between reader and transponder
0x05
Parameter assignment error, possible causes:
Unknown command
Incorrect parameter
Function not allowed
0x06
Air interface faulty
0x0C
The transponder memory cannot be written, possible cause:
Hardware fault (memory faulty)
Write-protected transponder
0x0D
Error in the specified memory address (access attempted to non-
existent or non-accessible memory areas).
0x13
Buffer overflow: Insufficient buffer available on the reader for saving
the command
0x14
Serious system fault (hardware fault)
0x15
Parameter assignment error: bad parameter in RESET command
0x18
Only RESET command is permitted
0x19
Previous command is still active
0x1C
Communications error, possible causes:
Antenna is already turned off / Antenna is already turned on
The antenna is turned of, the command cannot be executed on
the air
external antenna has a short-circuit or is not connected
0x1E
Incorrect number of characters in frame
0x1F
Running command canceled by "RESET" command
Command and message frames
2.11 Error messages
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6gt2821-4ac406gt2821-5ac406gt2821-6ac40

Table of Contents