Skoda Fabia II 2007 Workshop Manual page 60

Hide thumbs Also See for Fabia II 2007:
Table of Contents

Advertisement

Fabia II 2007 ➤ , Fabia II 2009 ➤ , Fabia II 2011 ➤ , Octavia II 2004 ➤ ...
Gearbox 09G - Edition 07.2014
– Press together the catches at the cable support of the selector
lever control cable -arrows- and pull out the selector lever
control cable from the cable support/gearbox.
– Lever off selector lever control cable in such a way that the
extremity can move freely.
Do not bend or buckle selector lever control cable.
For vehicles Octavia III and Yeti
– Unlock the quick-release lock -3- at the mounting bracket -2-
and unhook the selector lever control cable -1-.
– Unscrew the screws -arrows-, remove the support for the se‐
lector lever control cable -4- and place it to one side.
Note
Do not remove the circlip -5-.
Do not bend or buckle the selector lever control cable.
Continued for all vehicles
– Shift selector lever from "P" to "S".
– Check front boot on the selector lever cable control for dam‐
age, if necessary replace control cable.
– Shift selector lever into position "P".
Gearshift mechanism and selector lever control cable must
move smoothly when shifting gears. On some vehicles, you
can replace the selector lever control cable separately.
Selector lever control cable can be replaced as a separate part
or only on the vehicles:
⇒ "2.1.1 Summary of components - Gearshift mechanism -
Octavia II up to 10.2009", page 41
⇒ "2.1.4 Summary of components - Shift mechanism up to
10.2011 (Fabia II and Roomster)", page 47
– Carefully push the selector lever control cable onto the gear‐
shift lever and insert into the cable support/gearbox.
Setting
The selector lever control cable must be set, if:
♦ the selector lever control cable was removed from the gear‐
box,
♦ the engine was removed and installed or the gearbox was re‐
moved and installed,
♦ the selector lever control cable or the shift mechanism was
removed and installed,
♦ The position of the engine/gearbox was changed, e.g. during
a stress-free assembly of the unit.
– Shift selector lever into position "P".