Function 11. Stand-alone Option for SRC520
11.4 Power Supply
CAUTION
Ensure that AC power source of the Control Unit meets the following specifications.
Voltage
Frequency
Momentary Power
Interrupt
Power Consumption
Peak Current
Leakage Current
11.5 Extension Emergency Connector Unit
An Extension Emergency Connector Unit is to provide the same function as the
emergency connector of the Drive Unit for the Control Unit.
11.5.1 Appearance of Extension Emergency Connector Unit
The Extension Emergency Connector Unit is connected with MIB as shown below.
88
PC power cable for power source supply from the Drive Unit can not be used
when using the Control Unit only.
conforming to the specification of the connecting power source.
A power supply voltage switch at the rear panel of the Control Unit must be
set at the connecting voltage.
the equipment.
Item
MIB
Failure to do so will cause serious damage to
Specification
When the power supply voltage switch is set at [115] side
: AC100V to AC120V
When the power supply voltage switch is set at [230] side
: AC200V to AC240V
50/60Hz
Less than 10msec.
300W (The monitor is not connected.)
Approximately 40A (at AC200V)
3.5mA max.
Extension Emergency Connector
Junction Cable
Extension Emergency Connector Board
Use the proper PC power cable