Explanation of parameters
• Piston
This parameter serves to adjust the post-blow time of the stud feed blow air beyond the standard
measure when the pushing piston in the welding gun/welding head has moved forward to press the
stud out of the stud holder. A longer time setting is required when welding e.g. above the head to
achieve a trouble-free stud reload. The post-blow time can be set between 100ms and 2000 ms.
• Ready (only possible with "Feeder BMK" function in conjunction with a BMK feeder)
With UVR-300 feeder: This parameter serves to adjust the waiting period of the
hexagonal barrel in the feeding position with simultaneous post-vibration of studs.
Depending on the type of feeder, a basic setting between 500ms and 1000ms is
recommended.
With UVR-250 feeder: This parameter serves to adjust the after-run period of the
feeder when the light barrier has detected a stud in the stud escapement.
• Cont. (only possible with "Feeder BMK" function in conjunction with a BMK feeder)
This parameter serves to adjust the post-vibration period of the feeder to fill the outlet rail when a stud
has been brought in blow-off position. Depending on the type of stud, a basic setting between
500ms and 1000ms is recommended.
• BlAir
This parameter serves to adjust the delay time of the stud feed blow air after the injection piston in the
welding gun/welding head has moved back. After the set delay time, the stud feed blow air is
activated. This is necessary e.g. in the case of a short stud feed hose. The delay time can be set
between 100ms and 2000ms.
• Feeder (RUT)
This parameter serves to adjust the feeder type connected. UVRBMS and UVRBMK can be set as
feeder types.
R
5.4.5

Special function "Setting the feeder operation" (option)

This special function serves as a help for setting the feeder operation when the stud welder is
equipped with an optional automatic set.
For calling this special function, please proceed as follows:
• Simultaneously press "arrow down" and "arrow left" keys and keep them pressed.
• Turn on/off switch to the "I" position to switch the stud welder on and stop pressing the function keys.