6.1.1.6
RLT (reload time in milliseconds)
The reload time is the period of time the blow air valve requires for transporting the stud from the
universal feeder to the welding gun or welding head. The longer the blow air hose is, the higher you
have to set the reload time correspondingly. If automatic reload is not required, set value "0". The
reload time can only be used in connection with optional "automatic operation" (feeder connection).
• Select function "RLT" by pressing either function key "arrow left" (3) or "arrow right" (4).
• Now choose an appropriate value between 0 and 9900 ms in 100 ms steps by either pressing
function key "arrow up" (1) or "arrow down" (2).