Special Function "Setting The Feeder Operation - Soyer BMK-16 W Operating Instructions Manual

Stud welder
Table of Contents

Advertisement

5.4.5

Special function "Setting the feeder operation"

This special function serves as a help for setting the feeder operation when the stud
welder is equipped with an optional automatic set.
For calling this special function, please proceed as follows:
• Simultaneously press "arrow down" and "arrow left" keys and keep them pressed.
• Switch stud welder on with main switch.
• Stop pressing function keys.
Display when setting feeder type "BMS"
or:
Display when setting feeder type "BMK"
By using the function keys "arrow left" or "arrow right" you can move the slider in the
feeder's stud escapement to the left or right end position and thereby check the
setting. During this process, the operational states of possibly existing sensors are
displayed as "on" or "off". For further information, please refer to the operating
instructions of your universal feeder.
46
BMK-16 W

Advertisement

Table of Contents
loading

This manual is also suitable for:

P01329P01330

Table of Contents