ISSUE 2.0
Description
With External Paging, a user can broadcast announcements over paging equipment connected to
External Paging zones. When a user pages on of these external zones, the system broadcasts the
announcement over the speakers. Like Internal Paging, External Paging allows a user to locate
another employee or make an announcement without calling each extension individually.
The SL1000/SL1100 system allows up to three External Paging zones.
In PRG 10-03-02, set COI 2 of the 408M to 1 (= Audio port). Then COI port 2 works as External
Paging port in/out. A maximum of 3 Paging ports are available. (SL1000)
You can use the trunk ports CO2 for External paging. Audio port configuration can be done by system
programming. System can have up to 3 External Paging port, Base KSU port is assigned as Paging
Group1, Expansion KSU1 as Group2 and Expansion KSU2 as Group3. (SL1000)
When configuring a 3 KSU system, a maximum of 3 External Paging can be used by using Audio Out
jack at 084M-B1 unit. (SL1100)
Combined Paging
Use Combined Paging when you want to simultaneously Page into an internal and corresponding
external zone. For example, you can Page your company warehouse and outside loading dock at the
same time. Combined Paging is available for zones 1 ~ 3 and All Call. Refer to
page 1-542
for more on setting up Combined Paging. In addition, you can program a Function Key
as a Combined Paging key. Using the External Page Function Key, when an All Call External Page
Function Key is programmed, it includes both the external zones and the assigned internal zone(s). If
the internal page zone is busy or there are no extensions in a page group, the announcement is made
on the external zones only.
Relay Control
Relays can be used for External MOH, BGM resource, External Speaker, or Door Box control in
accordance with PRG 10-61-01 and PRG 10-61-02 settings.
In PRG 10-61-01 assign the Relay to the device to be paired with. (0: No setting, 1: External MOH, 2:
BGM, 3: External Speaker, 4: Door Box)
In case of External Speaker or Door Box, select Speaker or Box number to be used in PRG 10-61-02.
Conditions
• A Class of Service option is available in system programming to prevent display telephones from
showing incoming paging information. This allows the system to save processor time and speeds up
system operation.
• DID and DIL trunks do not ring external page speakers. Only trunks defined as normal in PRG
22-02-01 ring external page speakers.
• Paging keys can be assign on Programmable Function Keys and Direct Station Selection (DSS)
Consoles to simplify External Paging operation.
• If an Analog trunk circuit has a Trunk connected, you cannot use that circuit for External Paging.
• To have outside calls ring External Paging Zones at night, refer to the Night Service feature and
PRG 31-05.
• Talkback paging requires two-way speakers and require PRG 31-06-03 to be set to 0.