ISSUE 2.0
In PRG 42-03-12,
enter 0.

Figure 1-35 Single Line Terminal Room Monitoring

Operation
You must activate Room Monitor at the extension initiating the monitor and at the extension you want to
monitor. You can only listen to one extension at a time.
Multiline Terminals:
To activate Room Monitor from an idle Multiline Terminal (initiating extension):
1.
Press the Room Monitor key (PRG 15-07 or SC 851: 39).
2.
Dial the number of extension you want to monitor.
You can place and answer other calls while Room Monitor is active.
To activate Room Monitor from an idle Multiline Terminal (extension to be monitored):
1.
Press the Room Monitor key (PRG 15-07 or SC 851: 39).
Features and Specifications Manual
Start
Should a Single Line
Terminal user be able
No
to initiate and receive
Room Monitor?
In PRG 20-06-01,
assign Class of Service
to extensions.
Should the Room Monitor
servise code be changed
from the default setting of
770
No
Start
SL1000/SL1100
In PRG 42-03-12,
Yes
enter 1.
In PRG 11-14-17,
change the service
Yes
code to the desired
entry.