Answer Table 1
I
1-350
Type 3 (Date) Example
Answer Schedule 1
Answer Schedule 1 is a Range of
Days schedule that starts schedule
that runs every day from 8:30 AM to
5:00 PM.
Answer Schedule 2
Answer Schedule 2 is a Date
schedule that runs only on Christ-
mas day from 8:30 AM to 5:00 PM.
47-12-01 : Entry01 Schedule Type = 2
47-12-02 : Entry01 MB Ctg = 3
47-12-02 : Entry01 MB Num = 1
47-12-03 : Entry01 Day = 1 (Entry does not matter)
47-12-04 : Entry01 Start Day = 1 (Sunday)
47-12-05 : Entry01 End Day = 1 (Sunday)
47-12-06 : Entry01 Date (MMDD) = 0000 (Entry does not
matter)
47-12-07 : Entry01 Start Time = 0830 (8:30 AM)
47-12-08 : Entry01 End Time = 1700 (5:00 PM)
47-12-01 : Entry01 Schedule Type = 3
47-12-02 : Entry01 MB Ctg = 3
47-12-02 : Entry01 MB Num = 9
47-12-03 : Entry01 Day = 1 (Entry does not matter)
47-12-04 : Entry01 Start Day = 1 (Entry does not matter)
47-12-05 : Entry01 End Day = 1 (Entry does not matter)
47-12-06 : Entry01 Date (MMDD) = 1225 (December 25,
Christmas day)
47-12-07 : Entry01 Start Time = 0830 (8:30 AM)
47-12-08 : Entry01 End Time = 1700 (5:00 PM)