Room Monitoring from outside
< Program >
PRG 11-10-45: 710+1/0; Remote Monitor enable/disable.
PRG 13-04-01: Abbreviated Dial Data; set outside telephone number which makes room monitor.
PRG 13-04-03: 3; Transfer mode set "Remote monitor".
PRG 13-04-04: 200; Set monitored terminal number.
PRG 15-07-01: Set "#03" to Function key.
To start Room Monitor
1.
Press Speaker key + dial 710 + 1 + monitored terminal number, "200" and press Speaker key.
- OR -
S
Press the Function key (#03) + dial 1 + monitored dial number, "200" , the Function key turn on
Red (slow flash), and press Speaker key.
2.
Place incoming call from telephone which number is set at PRG 13-04-01.
3.
Room Monitor start at extension 200.
4.
By dialing
To stop Room Monitor
1.
Press Speaker key + dial 710 + 0 + monitored terminal number, "200".
- OR -
Press the red flashing Function key (#03) + dial 0 + monitored dial number, "200".
2.
Place outside call from telephone which number is set at PRG 13-04-01.
3.
Call ring at extension 200.
Remote Inspection
< Program >
PRG 11-10-49: 719; Auto Dial Setting for Remote
PRG 20-45-01: 200; Remote Inspection terminal, 200
PRG 20-45-02: 12:00; Ringing start time, 12 o'clock noon
PRG 20-45-03: 3; ringing continue time, 3 minutes
PRG 20-45-04: 999; Speed dial bin number, 999
PRG 20-45-05: 1; VRS message number when inspected extension answered, 1
PRG 20-45-06: 2; VRS message number when emergency call destination answered, 2
PRG 20-45-07: 3; Times of auto repeat dial, 3
PRG 20-45-08: 30; Auto dial calling time, 30 sec
PRG 20-45-09: 30; Interval of Auto Dial, 30 sec
Set up Remote Inspection
1.
Press Speaker key + dial 719 at Multiline Terminal.
2.
Dial Remote Inspection terminal number (1-6).
3.
Dial 1 (set).
4.
Dial Remote Inspection extension number, "200".
5.
Dial Ringing start time, "1200".
6.
Dial ringing continue time, "03".
7.
Dial Speed dial bin number to use, "999".
8.
Dial emergency call destination number "xxx-xxx" and press Hold key.
1-620
*
from outside it is possible to make both way talk.