Hotel/Motel - Toll Restriction (When Checked In) - NEC SL1000 Features And Specifications Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 2.0
Hotel/Motel - Toll Restriction (When
Description
With Toll Restriction (When Checked In), you can control guest's long distance dialing automatically
when they check in. This option allows you to set up two completely different Toll Restriction modes.
The first mode determines the type of call your staff can place from a room telephone when the room
is checked out (Service Code 739). This is the business mode Toll Restriction. The second mode sets
the Toll Restriction limits for your guests as soon as you check them in (Service Code 738). This is the
hotel mode Toll Restriction.
In the checked out mode, for example, you may want to allow your staff to call locally and within your
area code. This would allow them to contact suppliers and other service providers without going to the
front desk each time. In the checked in mode, however, you may want to completely restrict outgoing
calls and force your guests to use your metered services. (This can also tie into
page
1-315.)
In many cases, such simplified Toll Restriction scenarios may be adequate. However, since each
mode uses the full abilities of the system Toll Restriction programming, you can make the calling
restriction as elaborate as it needs to be.
Toll Restriction (When Checked In) also allows you to change the Toll Restriction of a room telephone
while the room is checked in. This allows you to provide more permissive Toll Restriction to high
priority guests. It also allows you to enforce less permissive dialing privileges to guests if you suspect
the potential for abuse.
If a room Toll Restriction is changed using access code 737, that room keeps the new setting until it is
either changed using access code 737 or in system programming.
The following diagram shows the basic operation of Toll Restriction (When Checked In). When
checked in, the room telephone follows the Check In Toll Restriction Level (set in PRG 42-02-02).
When checked out, the room telephone follows the normal Toll Restriction Level (set in PRG
21-04-01). Both levels interact with the dialing restrictions set up in PRG 21-05 and 21-06. For more
details, refer to
Setting Up on page
Features and Specifications Manual
1-320.
SL1000/SL1100
Checked In)
Single Digit Dialing on
1-317
H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl1100

Table of Contents