NEC SL1000 Features And Specifications Manual page 449

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 2.0
In PRG 20-09-03, set the
extension's COS to '0'.
In PRG 20-13-23,
set the extension's
COS to '0'.
In PRG 22-02-01,
enter 0.
In PRG 22-04-01,
do not assign
extension to PRI
trunk's Ring
Group.
Features and Specifications Manual
A
Should the sub-address
No
ID be display for
incoming calles?
Should an extension
No
be able to display the reason why
a vall is transferred to it?
Define the extension's Class
of Service in PRG 20-06-01.
Is SMDR used?
No
Should all PRI
Yes
Trunks ring the same
extensions?
In PRG 22-05-01, assign all the
trunks on a PRI ETU to the same
Ring Group.
In PRG 14-07-01 and PRG 15-06-01, set
up the trunk Access Maps for PRI trunks.
Should extension
ring for incoming
No
calls on PRI trunk?
In PRG 14-01-01,
assign names to
trunks to make
identification
easier.
Go to
B
SL1000/SL1100
In PRG 20-13-23, set the
Yes
extension's COS to '1'.
In PRG 20-13-23,
Yes
set the extension's
COS to '1'.
In PRG 35-02-15, enter '0' to
print Caller ID Number, "1" DID
Yes
Calling Number or '2' Caller ID
Name.
In PRG 35-02-16, enter '0' to
print the trunk port name
assigned in PRG 14-01-01 or
enter '1' to print the
received dialed number.
In PRG 22-02-01, enter 3.
Refer to the
No
Programming Manual
or Networking Manual.
In PRG 22-04-01,
assign extension
Yes
to PRI trunk's Ring
Group.
For each extension in the Ring
Group, in PRG 22-06-01, enter
'1' for each time mode when
the extension should ring.
I
1-439

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl1100