5540F/YB5515 SERVICE MANUAL
250 Hours of Operation (Monthly)
Inspect the Hydraulic Hoses
Inspect hydraulic hose assemblies for leaks, damaged
fittings and worn exterior. Do not use your hands to check for
hydraulic leaks. Hydraulic oil under pressure can cause
serious injury or possible death. Use a piece of cardboard or
other material as a deflector to detect leaks. Replace any
problem hose before beginning work.
GROVE
Clean Battery and Cables
1.
Remove the battery compartment cover.
p1652
Published 10-21-2010, Control# 198-04
PREVENTATIVE MAINTENANCE
Battery Location
5
FIGURE 5-27
5-17