8.5

PDU3 Fuses

Two fuses for the incoming AC power lines are located in the fuse compartment at the AC
Power Inlet area, located between the power cable connector and the On/Off switch.

Procedure to Remove Fuse Holder

1. Turn off AC power to the PDU3 and disconnect the power cord from the AC
power source.
2. Remove the AC power cord from the socket on the AC Power Inlet area.
3. To remove the fuse holder, insert a small flat-blade screwdriver into the slots on
the opposite sides of fuse holder, then press down and pull out the fuse holder.
4. To reinstall the fuse holder, insert it in place, then press down firmly until the
entire holder snaps into position.
Fuse
AC Line fuses at AC Power
Inlet
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
WARNING:
Only skilled or instructed personnel should
attempt to change any fuses. Always replace blown fuses
with new fuses of the same type and rating.
Table 8-1. PDU3 Fuse Ratings
Quantity
2
Adept Python Modules User's Guide, Rev. E
Rating
Type
8 Amp
IEC 127-style
Time Lag
5 x 20 mm
PDU3 Fuses
125

Advertisement