Light Indicator - AGFA Jeti Tauro H3300LED Series Operator's Manual

Hybrid uv inkjet printer
Table of Contents

Advertisement

Interlock Operation
When all the doors and covers are closed, the system is safe and operational. This is the mandatory
state for production.
When the front operator access doors are opened while the system is idle (no motion enabled) the
system stays in a safe state. The doors must be closed and a system initialization initiated using the
Re-init button in the system status message screen before submitting a new job. In this condition, the
system initialization takes a few seconds.
When an interlocked door or cover is open while the system is printing, an emergency stop takes
place. This emergency stop immediately stops all axis of movement in the accessed area (for example,
movement of shuttle and transport belt) when opening a main access door. The system disables media
transport belt and shuttle movement. The access doors must be closed and a system initialization initi-
ated using the Re-init button in the system status message screen before submitting a new job. In this
condition, the system initialization takes a few minutes.

Light Indicator

The Jeti Tauro H3300LED features an annunciator light on the top right of the engine. The light reports
status as indicated in Table.
Table: Annunciator Light Modes
Engine Status
Power off
Initializing
Ready
Preparing
Printing
Stand by
Error
Whether the Jeti Tauro H3300LED is initializing, printing or in error, a blinking state
always calls for the user's attention.
Agfa Graphics
Jeti Tauro H3300LED Operator Manual
Light Color
Red
Orange
Green
Green
Green
Orange
Red
Revision 1.0
Fig.1-13: Location of the Left indicator (media
Behavior
Static
Blinking
Static
Static
Blinking
Static
Blinking
Chapter 1
11

Hide quick links: