ProSoft Technology MVI69-GSC CompactLogix User Manual page 39

Generic ascii serial communication module
Table of Contents

Advertisement

MVI69-GSC ♦ CompactLogix or MicroLogix Platform
Generic ASCII Serial Communication Module
[Section]/Item
Tx Swap Bytes:
[Section]/Item
[GSC Port 1]
Enabled:
Type:
Baud Rate:
Data Bits:
Stop Bits:
RTS On:
RTS Off:
Handshaking:
Rx Term Char Count:
Rx Term Characters:
ProSoft Technology, Inc.
Value
Range
Yes or No
Value
Range
Yes or No
0 to 15
From selected
list of codes
5 to 8
1 or 2
0 to 65535
0 to 65535
NONE,
RTS/CTS,
DTR/DSR or
XON/XOFF
0 to 12
List of up to
12 integer
values
Description
This parameter specifies if the data to be
transmitted out the port will have the bytes
swapped from the data presented across the
backplane.
Description
GSC port definition header
This parameter defines if this port will be utilized.
If the parameter is set to No, the port is disabled.
A value of Yes will enable the port.
This parameter specifies the receive termination
characteristics for the port. This value is bit
mapped as follows: Bit 0 = Termination
character(s) used, Bit1=Message timeout used,
Bit2=Intercharacter delay timeout used and
Bit3=Packet size limit used. If the parameter is set
to zero, the port is placed in stream mode.
This is the baud rate to be used on the port. Enter
the baud rate as a value. For example, to select
19K baud, enter 19200. Valid entries for this field
include: 110, 150, 300, 600, 1200, 2400, 4800,
9600, 19200, 384 or 3840 for 38400, 576 or 5760
for 57600 and 115 or 1150 for 115200.
This parameter sets the number of data bits for
each word used by the protocol. Valid entries for
this field are 5, 6, 7 and 8.
This parameter sets the number of stop bits to be
used with each data value sent. Valid entries for
this field are 1 and 2.
This parameter sets the number of milliseconds to
delay after RTS is asserted before the data will be
transmitted. Valid values are in the range of 0 to
65535.
This parameter sets the number of milliseconds to
delay after the last byte of data is sent before the
RTS modem signal will be set low. Valid values
are in the range of 0 to 65535.
This parameter specifies the handshaking used on
the port. The values are as follows: None=No
hardware or software handshaking, RTS/CTS
hardware handshaking, DTR/DSR hardware
handshaking and XON/XOFF software
handshaking.
This parameter is used if bit 0 of the Type
parameter is set. This value (0 to 12) defines the
number of termination characters used to define
the end of received message.
This array of 12 integer values representing the
characters used to define the termination
characters at the end of each received message.
The number of characters to be used in the array
is set in the RTermCnt parameter.
Contents
User Manual
Page 39 of 83