Sign In
Upload
Manuals
Brands
ProSoft Technology Manuals
Control Unit
MVI69E-MBTCP
ProSoft Technology MVI69E-MBTCP Manuals
Manuals and User Guides for ProSoft Technology MVI69E-MBTCP. We have
1
ProSoft Technology MVI69E-MBTCP manual available for free PDF download: User Manual
ProSoft Technology MVI69E-MBTCP User Manual (150 pages)
CompactLogix Platform Modbus TCP/IP Enhanced Communication Module
Brand:
ProSoft Technology
| Category:
Control Unit
| Size: 3 MB
Table of Contents
Your Feedback Please
2
Content Disclaimer
2
Important Safety Information
3
Table of Contents
5
1 Start here
9
System Requirements
10
Deployment Checklist
11
Setting Jumpers
11
Installing the Module in the Rack
12
Package Contents
15
2 Adding the Module to Rslogix
17
Creating the Module in an Rslogix 5000 Project
17
Creating a Module in the Project Using an Add-On Profile
18
Creating a Module in the Project Using a Generic 1769 Module Profile
21
Installing Prosoft Configuration Builder
24
Generating the AOI (.L5X File) in Prosoft Configuration Builder
25
Setting up the Project in PCB
25
Creating and Exporting the .L5X File
27
June
28
June
29
Creating a New Rslogix 5000 Project
30
Importing the Add-On Instruction
31
Adding Multiple Modules in the Rack (Optional)
34
Adding an Additional Module in PCB
34
Adding an Additional Module in Rslogix 5000
36
3 Configuring the MVI69E-MBTCP Using PCB
43
Basic PCB Functions
44
Creating a New PCB Project and Exporting an .L5X File
44
Renaming PCB Objects
44
Editing Configuraiton Parameters
44
Printing a Configuration File
46
Module Configuration Parameters
47
Module
47
MBTCP Servers
48
MBTCP Client X
50
MBTCP Client X Commands
51
Ethernet 1
55
Static ARP Table
56
Downloading the Configuration File to the Processor
57
Uploading the Configuration File from the Processor
60
4 MVI69E-MBTCP Backplane Data Exchange
63
General Concepts of the MVI69E-MBTCP Data Transfer
63
Backplane Data Transfer
64
Normal Data Transfer
65
Write Block: Request from the Processor to the Module
65
Read Block: Response from the Module to the Processor
65
Read and Write Block Transfer Sequences
66
Data Flow between the Module and Processor
70
Server Mode
70
Master Mode
72
5 Using Controller Tags
75
Controller Tags
75
MVI69E-MBTCP Controller Tags
76
User-Defined Data Types (Udts)
76
MVI69E-MBTCP User-Defined Data Types
77
MBTCP Controller Tag Overview
79
Mbtcp.config
79
Mbtcp.data
80
Mbtcp.control
80
Mbtcp.status
86
Mbtcp.util
90
6 Diagnostics and Troubleshooting
93
Ethernet LED Indicators
93
LED Status Indicators
94
Clearing a Fault Condition
94
Troubleshooting
95
Connecting the PC to the Module's Ethernet Port
96
Setting up a Temporary IP Address
96
Using the Diagnostics Menu in Prosoft Configuration Builder
98
Diagnostics Menu
100
Monitoring General Information
101
Monitoring Backplane Information
101
Modbus Server Driver Information
102
Monitoring Data Values in the Module's Database
103
Modbus Client Driver Information
103
Communication Error Codes
104
Standard MODBUS Protocol Exception Code Errors
104
Module Communication Error Codes
104
Command List Entry Errors
104
MBTCP Client-Specific Errors
105
Connecting to the MVI69E-MBTCP Webpage
105
7 Reference
107
Product Specifications
107
General Specifications - Modbus Client/Server
108
Hardware Specifications
108
About the Modbus TCP/IP Protocol
109
Modbus Client
109
Modbus Server
110
Function Codes Supported by the Module
110
Read Coil Status (Function Code 01)
111
Read Input Status (Function Code 02)
112
Read Holding Registers (Function Code 03)
113
Read Input Registers (Function Code 04)
114
Force Single Coil (Function Code 05)
115
Preset Single Register (Function Code 06)
116
Diagnostics (Function Code 08)
117
Force Multiple Coils (Function Code 15)
119
Preset Multiple Registers (Function Code 16)
120
Floating-Point Support
121
ENRON Floating Point Support
122
Configuring the Floating Point Data Transfer
122
Function Blocks
127
Event Command Blocks (2000 to 2019)
128
Client Status Request/Response Blocks (3000 to 3019)
129
Event Sequence Request Blocks (4000 to 4019)
130
Event Sequence Command Error Status Blocks (4100 to 4119)
131
Get Queue and Event Sequence Block Counts Block (4200)
132
Command Control Blocks (5001 to 5016)
132
Add Event with Data for Client Blocks (8000)
133
Get Event with Data Status Block (8100)
134
Get General Module Status Data Block (9250)
135
Set Driver and Command Active Bits Block (9500)
136
Get Driver and Command Active Bits Block (9501)
137
Pass-Through Formatted Block for Functions 6 and 16 with Word Data Block (9956)
138
Pass-Through Formatted Block for Functions 6 and 16 with Float Data Block (9957)
139
Pass-Through Formatted Block for Function 5 (9958)
139
Pass-Through Formatted Block for Function 15 (9959)
140
Pass-Through Formatted Block for Function 23 (9961)
141
Pass-Through Block for Function 99 (9970)
141
Set Module Time Using Received Time Block (9972)
142
Pass Module Time to Processor Block (9973)
143
Reset Status Block (9997)
143
Warm-Boot Control Block (9998)
144
Cold-Boot Control Block (9999)
144
Ethernet Port Connection
145
Ethernet Cable Specifications
145
8 Support, Service & Warranty
147
Contacting Technical Support
147
Warranty Information
148
Index
149
Advertisement
Advertisement
Related Products
ProSoft Technology MVI69E-GEC
ProSoft Technology MVI69E-GSC
ProSoft Technology MVI69E-LDM-MQTT
ProSoft Technology CompactLogix MVI69E-MBS
ProSoft Technology inRax MVI69-101M
ProSoft Technology MVI69-GSC CompactLogix
ProSoft Technology MVI69-GSC MicroLogix
ProSoft Technology MVI69-GEC
ProSoft Technology inRAX MVI69-S3964R
ProSoft Technology MVI69L-MBTCP
ProSoft Technology Categories
Control Unit
Gateway
Wireless Router
Network Hardware
I/O Systems
More ProSoft Technology Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL