Brother PR1055X Operation Manual page 183

Hide thumbs Also See for PR1055X:
Table of Contents

Advertisement

Symptom
Probable Cause/Remedy
The upper thread breaks.
The needle is not correctly installed.
The needle set screw is loose.
The needle is bent or blunt.
The area around the hole in the needle plate is
damaged.
1 Scratches/Burrs
• Replace the needle plate.
The needle is touching the needle plate.
1 Needle
2 Needle plate hole
3 Needle touching hole
The presser foot is set too high and not correctly
positioned.
The needle hits/touches the presser foot.
The area around the embroidery foot hole is
damaged.
1 Scratches/Burrs
• Replace the presser foot.
Using a specialty thread like a metallic thread.
• Slow down the machine embroidery speed.
Page
Sliding surface on hook is not smooth. There are
burns on it.
176
176
176
*
1 Hook race area
The thread is loose in the hook area.
The play between the hook and the race is too
much.
The hook does not rotate smoothly.
• Remove lint, clean and apply oil.
The space between the hook stopper and the
hook cannot be adjusted.
The upper thread is not threaded correctly.
*
• Pull the upper thread by hand from below the
presser foot, and check that the thread moves
smoothly. If the thread does not move
*
smoothly, it is not correctly threaded. Un-
thread the machine and re-thread the machine.
Make sure the thread is correctly positioned in
*
the needle bar thread guide.
Upper thread is not positioned in upper or middle
thread guide.
• Make sure thread passes completely under
upper and middle thread guide.
There are knots or tangles in the thread.
• Remove any knots or tangles.
The upper thread tension is too high.
The bobbin thread tension is incorrect.
The thread does not roll out of the bobbin case
smoothly.
89
The bobbin case is damaged.
• Replace the bobbin case with a new one.
The bobbin thread is not wound correctly.
• Check that the bobbin is wound so that it is
about 80% full and that the thread is evenly
wound. If the bobbin is not correctly wound,
replace the bobbin with one that is correctly
wound or rewind the bobbin.
Symptom
Probable Cause/Remedy
APPENDIX
Page
*
173
*
173, 178
*
82
5
82
118
116
33
33
181

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents