Adjusting The Fold Mirror - Christie Boxer 4K Series Service Manual

Hide thumbs Also See for Boxer 4K Series:
Table of Contents

Advertisement

6. To focus the right boresight guide, adjust the green boresight screw.
7. To focus the left boresight guide, adjust the yellow boresight screw.
8. To continue to refine the focus, repeat steps 5 to 7.
9. Before adjusting the stabilization screws, close the shutter.
10. To maintain the adjustments, lock the stabilization screws.
When locking the screws, start with the top stabilization screw and turn it so it just touches the
base. Repeat for the other two stabilization screws. Continue to adjust the locking screws until
they are tight.

Adjusting the fold mirror

Fold mirror adjustment must be completed by trained personnel and with the projector in single lamp
mode.
Notice. If not avoided, the following could result in property damage.
Misalignment of the fold mirror may cause permanent damage to the product.
1. From the Test Pattern menu, select the Integrator Rod test pattern.
Boxer 4K Service Guide
020-101699-04 Rev. 1 (02-2018)
Copyright
2018 Christie Digital Systems USA, Inc. All rights reserved.
©
Service setups
20