Purge Pump (PL2.0.7)
Phaser 8400/8500/8550/8560 Color Printer Service Manual
1.
Remove the Left Side Cover (page 8-6).
2.
Disconnect the air hose from the Purge Pump.
3.
Disconnect the harness from the Purge Pump.
4.
Remove 3 screws to remove the Purge Pump.
Replacement Note
Screws in plastic are torqued to 12 in. lbs., metal to 15 in lbs., unless
otherwise specified. Irreversible damage can result from over
tightening screws into plastic parts.
Service Parts Disassembly
s8500-097