19,0Xx.xx Errors - Printhead Calibration Faults - Xerox PHASER 8500 Service Manual

Xerox printer user manual
Hide thumbs Also See for PHASER 8500:
Table of Contents

Advertisement

Error Messages and Codes

19,0XX.xx Errors - Printhead Calibration faults.

3-32
19,001.46:
HFD server failed due to NVRAM operation. This fault only occurs
when the printer is set in manufacturing mode. Program fault.
19,002.47:
Attempted to perform a Printhead operation without the Printhead
NVRAM data being loaded.
19,003.48:
Scale and offset error is too large. The voltages measured have
more than a 20% error from their expected values. Something is wrong with
the Electronics Module or the Wave Amplifier.
19,004.40:
The Printhead and the Electronics Module do not match. Contact
escalated Service Support Representative for information to clear fault.
19,005.41:
A posssible static discharge from the Pick Clutch to the
Electronics Module.Characterized by:
19,005.41 error code displayed on the Control Panel
Printer hangs while printing with the Electronics Module Fan on full
Low humidity
Occasional Jam Behind the Front Cover messages, usually accompanied
by error 19,005.41 in Fault History
To prevent these discharges, a Grounding Clip (P/N 650442700) was added
between the Y-Axis Motor mount and the Pick Clutch. Check that this clip is
installed and contacts the metallic portion of the Pick Clutch.
Note
The Grounding Clip is factory installed in later versions of 8500/8550
models and in all 8560 models.
Phaser 8400/8500/8550/8560 Color Printer Service Manual