4 Parts Replacement
4.7.2
Replacing Pump Cap Assembly
NOTE
Before removing the pump cap assembly, remove the following parts.
• R side cover:
• Flushing box:
• Maintenance base assembly:
• Ink holder cover:
1. Remove the screw retaining the pump cap assembly to the maintenance base 1 (pan-head screw with
spring washer and flat washer M3
1
2. Replace the pump cap assembly
3. To reassemble the unit, reverse the removal procedure.
"4.2.1 Removing R Side Cover" p.4-6
"4.7.4 Replacing Flushing Box Assembly" p.4-54
"4.7.1 Removing Maintenance Base Assembly" p.4-47
"4.2.4 Removing Ink Holder (I/H) Cover" p.4-11
×
6: 4pcs).
RJ-901C/RJ-900C Maintenance Manual
No.
1
back-side
2
3
4-52
Part name
Pump cap assembly screw
Maintenance base 1
Pump cap assembly