19,0XX.6x Errors - Waveform Program Faults
21,000.69 Errors - Diagnostic Code Version Mismatch
22,0XX.6x Errors - Jam Codes
23,0XX.6x Errors - NVRAM Fault
26,0XX.6x Errors - Printing Faults
Phaser 8400/8500/8550/8560 Color Printer Service Manual
19,005.63:
Wave Amplifier overcurrent. This error can occur in too-low
humidity environments. Printer self-resets.
Troubleshooting Procedure for Printhead Calibration
Step
Questions and Actions
1
For 19,005.41 errors:
Check that the Ground Clip (650442700) is
properly installed at the Y-Axis Motor
mounting and contacts the metallic portion
of the Pick Clutch.
Is the Ground Clip properly installed?
Check and reseat all wiring to the Printhead.
2
Did this correct the problem?
19,001.68 thru 19,039.61:
a.
Reset NVRAM, and then retest.
b.
Replace the NVRAM chip.
c.
Replace the Printhead.
The diagnostic firmware does not match the engine firmware. Update the
diagnostic firmware for the printer. If a code updated ROM daughter board is
installed on the main board, remove the board so the printer boots using the
main board's code and diagnostics.
For jam codes, "Jam Codes" on page 3-48.
1.
Reset NVRAM, and then retest.
2.
Replace the NVRAM.
Reboot the printer if one of these faults occur.
Go to Step 2.
Complete.
Waveform Printhead calibration program faults.
Error Messages and Codes
Yes
No
Correct or
replace the
Ground Clip.
Replace in
this order:
Printhead
■
Electronics
■
Module
3-33