Software Configuration - Daikin LXE10E-A Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru

3.6.2 Software configuration

MAIN MENU
LOGGER DATA
DOWNLOAD
CONTAINER I.D. SET CONTAINER I.D.
/HEADER
MAINTENANCE
& REPAIR
USDA
(3-PULP
SENSORS)
COLD
-TREATMENT
4-PULP
SENSORS
COLD
-TREATMENT
SUB MENU
TRIP DATA
USDA DATA
4-PULP SENSORS DATA
PTI DATA
ALL DATA AFTER
TRIP-START
/HEADER
-From DISK
CHANGE CONTAINER I.D.
-From Keyboard
CHANGE CONTAINER
HEADER
-From Keyboard
CHANGE CALENDAR
DISPLAY CURRENT
OPERATING DATA
DISPLAY CURRENT
ALARM
DISPLAY ALARM LOG
DISPLAY
TEMPERATURE CHART
REPLACE BATTERY
CALIBRATION
USDA SENSORS
DISPLAY TEMPERATURE
CHART
CALIBRATION
4-PULP SENSORS
DISPLAY
TEMPERATURE CHART
Explanation of functions
Data recorded in the logger is read
from the controller onto the personal appears on the
computer (disk or hard disk).
(This operation is called the
download).
The logger header (set point temperature, Disk
cargo name, destination and other
information) is changed.
¡Data previously saved on disk is
transmitted to the controller.
The container No. (container ID)
set in the controller is changed.
The logger header is changed.
The internal clock on the
controller is changed.
¡The controller clock is based on GMT
(Greenwich Mean Time)
Controller sensor values, operation of
internal relay and opening rates of SMV
and EV are displayed on the screen.
Detected alarms are displayed.
Information of alarm recorded
in the logger is displayed.
Fluctuation of control temperature
which has been recorded in the logger
is displayed in a graphic chart.
The back-up battery replacement
day is set and displayed.
The pulp sensor (USDA sensor) to The ice bath
be used for low temperature
transportation is calibrated.
Fluctuation of the pulp sensor
(USDA sensor) temperature which
has been recorded in the logger is
displayed in a graphic chart. Summary
report of trip data is indicated.
The pulp sensor (USDA sensor)
to be used for low temperature
transportation is calibrated.
Fluctuation of the pulp sensor
(USDA sensor) temperature which
has been recorded in the logger is
displayed in a graphic chart. Summary
report of trip data is indicated.
3-40
Remarks
No information
screen at this time.
/Controller
Input from
keyboard
Input from
keyboard
Conversion from
personal computer
built-in clock
Record on disk
is enabled.
Record on disk
is enabled.
Setting can be also
made on the
control panel.
is used.
The ice bath
is used.