Defrosting Mode - Daikin LXE10E-A Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru

2.5.3 Defrosting mode

Defrosting range
●Compressor
●Evaporator fan
●Condenser fan
●Defrosting solenoid valve ON
●Hot gas solenoid valve ON
Operation of magnetic contactor and solenoid valve
Component name
Compressor
Evaporator fan. High speed
Evaporator fan. Low speed
Condenser fan
Liquid solenoid valve
Economizer solenoid valve
Injection solenoid valve
Hot-gas solenoid valve
Defrost solenoid valve
Discharge gas by-pass solenoid valve
Reheat solenoid valve
Suction modulating valve
Electronic expansion valve
Note) ※1: Charging control
※2: Release control
※3: RSV:ON EOS>15˚C
Start defrosting
Yes
●Defrost lamp (red) ON
●Pump down
ON
OFF
ON/OFF
Is terminating
condition OK?
Yes
Defrosting lamp (red) OFF
Evaporator fan On after delay of 60 seconds
Return to frozen, chilled or partial
frozen operation
CC
EFH
EFL
CF
LSV
ESV
ISV
HSV
DSV
BSV
RSV
SMV
EV
2-22
No
Pump down
Defrosting
ON
OFF
ON
ON/OFF ※2
OFF
ON
OFF
ON/OFF ※1
OFF
OFF
OFF
OFF
ON/OFF ※3
100%
200〜2000pls
ON
OFF
OFF
OFF
ON
ON
OFF
100%
0pls

Advertisement

Table of Contents
loading

Table of Contents