Daikin LXE10E-A Service Manual page 195

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
Setting item
Current
indication mode
MODE
M
G-SET
operation
MODE
MODE
M
M
Automatic pump
down operation
MODE
M
Dehumidification
ON-A ・ OFF setting
Note) Refer to the detail of automotic pump down function in the "Section 4.1.3(2)" of Service manual.
CAUTION
1.To apply the dehumidification control, be sure to set "ON-A".
2.ON/OFF of the reheating coil and DE-HUMID LED lit/unlit are not
synchronous.
3.When the dehumidification ON-A・OFF is set to ON, G-Set
operating mode will be skipped.
LED panel
––
ON, OFF
ON, OFF
OFF, ON-A
8-12
LCD panel
––
diSPOFF
P down
dHu
Setting method
––
Select "ON" by using
or
key, and
press the
key to
determine the setting.
Select "ON" by using
key and
key,
and press the
key to
determine the setting.
Select "ON-A" by using
key and
key,
and press the
key to
determine the setting.