8.2.4 Special controller setting (Applicable models:LXE10E-A23(A,B))
1.Setting flow chart
This configuration setting flow shall be utilized, when
CASE 1) USDA transportation setting is required (※10 Optional Function Setting on page 3-29)
CASE 2) Container ID shall to be subjected to change from another container for emergency use.
(※13 Container ID & Time Setting)
CASE 3) Controller is replaced to new one. (All setting in ※10-13 (page 3-42)shall be set.)
NOTE 1 : All initial settings are pre-setted, when the unit is delivered.
2 : In case to complete the setting change, CIRCUIT BREAKER shall be turned off.
Power OFF
Circuit Breaker ON
Unit OFF
I/O ON
All lights on
(for 3 sec.)
for 3 sec.
for 3 sec.
Preparation
(for 18 sec.)
USDA: OFF (or 3 or 4)
S
dHU: OFF (or ON)
CASE 1
for 3 sec.
※ 10
PTI
Optional
Function
Setting
DECOS3: D (or C or B or A)
S
Log. Interval: 60 (or 15 or 30 or 120)
S
REC SEN: ON (or OFF)
S
OC-SET: Sing (or Dual)
S
HP: 10 (or 5)
S
DISP: OFF (or ON)
S
COMP: 100 (or 33)
S
REHEAT: OFF (or ON)
S
FASEN: OFF (or H or L)
CASE 3 (Refer to 3.8.2)
Circuit Breaker OFF
after setting change
(
I/O
OFF when no setting changed)
for 3 sec.
for 3 sec.
※ 11
Basic
Function
Setting
CHARTLS: ON (or OFF)
S
USDA 1/2: 1 (or 2)
S
H001~H006
S
d-1**~d-2**
S
C/F : C (or F)
8-26
for 3 sec.
※ 12
※ 13
Optional
Input Data
Condition
Setting
Container I.D
S
Controller
Time
CASE 2