F.pti Specification - Daikin LXE10E-A Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
8.2.12 F.PTI specification (Applicable models:LXE10E-A12(AtoE) and A28)
In order to perform F.PTI operation, this unit is designed by adding the following ① to ④ functions to the
standard specification, which are enclosed with a dotted rectangular
①Entry of set temperature while in F.PTI mode
Press the   key. You should see the temperature
setting screen.
After the completion of the temperature setting, press
the
key to commence the F.PTI operation.
FULL PTI
SHORT PTI
MANUAL PTI
②Display of set temperature and pull-down period while in F.PTI mode
Scrolling sensor display mode with the UP or DOWN key will display the temperature
and period after DRS.
Display on LCD
HPT ○○
Use the
Temp. setting
temperature.
(variable)
Setting range: -18° C to -30° C (in 1° C increments)
     
(The temperature is displayed on LCD.)
 Furthermore, the defrost interval returns to 12 hours.
When the F.PTI operation terminates, the set temperature will
automatically return to the default value, that is, -18° C.
Set temperature
SP −○○
In the case of 2 hours and 5 minutes
8-40
as shown below.
DEHUMID
DEHUMID
M
S
or
key to change the set
Pull-down period
T 02H05
I/O
I/O