8.2.7 G-SET operation 1

(Applicable models:LXE10E-A11,A20,A26(AtoC),A18(A,B),A30 and A35(A,B))
Generator setting operation
qPress the MODE
wSelect "11", "12", "13", "14", "15" (kVA) or "OFF" indicated on the LED display using the
the
key, and press the
operation starts so that the energy consumption is saved to be the selected value (kVA) or lower.
※If "OFF" is pressed in the procedure wabove, the energy saving operation will be cancelled.
※If the power supply is turned off when the setting mode is set to exception of 12(kVA), the setting is
returned to 12(kVA) automatically.
※Even though the value is expressed in kVA, this is actually a value in kW.
Setting item
Current
indication mode
G-SET
G-set operation
G-SET
G-SET
Automatic pump
down operation
8.2.8 G-SET operation 2 (Applicable models:LXE10E-A8,A9 and A19)
Generator setting operation
①Press the G-SET key.
②Using
and
, select "11", "12", "13", "14", "15" (KVA) or "OFF", and determine it with
consumption reducing operation will be applied under the selected value.
To reset Generator setting operation, set OFF in the above operation step ②.
When Generator setting operation is set, it will not be reset even if the power supply is turned off. (The setting is
held.)
MODE
M
key.
key to determine the setting, then the energy saving
LED panel
––
Energy saving set point
OFF, 11, 12, 13, 14, 15
unit: kVA
Note) Even though the
value is
expressed in kVA,
this is actually a
value in kW.
ON, OFF
LCD panel
––
G-SET
P down
8-32
key or
Setting method
––
Select the energy
saving set point by
using
or
key,
and press the
key
to determine the
setting.
Select "ON" by using
key and
key,
and press the
key
to determine the
setting.
key. The energy

Advertisement

Table of Contents
loading