3. Dehumidification control setting
This unit features the dehumidification function. Therefore, it is necessary to set whether the
dehumidification control is to be executed or not according to the cargo to be transferred.
You can set whether the dehumidification control is to be executed or not by operating the display
panel of controller.
3.1 Description of setting
Whether the dehumidification control is to be executed or not is switched over according to the setting
of dehumidification control parameter "dHu" under the "7. G-SET operation / Automatic pump down
operation mode / Dehumidification ON-A・OFF setting"
Dehumidification
control
To execute
Not to execute
Note) The dehumidification control clearing function is a function to automatically change the
setting of dehumidification control to OFF if the main unit power supply turns OFF for a
period of 48 hours or more. The ON/OFF setting of the dehumidification control clearing
function "dHU-CAN" is made while in optional function setting mode. For details of setting
procedure, refer to information (on page 3-26). The setting of dehumidification control "dHU"
can also be made while in optional function setting mode.
CAUTION
1.ON/OFF of the reheating coil and DE-HUMID LED lit/unlit are not
synchronous.
2.To apply the dehumidification control, be sure to set "ON-A".
Setting of
dehumidification
DE-HUMID LED
control "dHu"
ON-A (Applied)
off (Not applied)
8-38
Case of the unit without the
humidity sensor
Note) If the following conditions
are both satisfied, the
dehumidification control
ON
will automatically be set to
"OFF" (dehumidification
control clearing function).
¡
The "dHU-CAN" is set to ON.
¡
48 hours or more lapsed after
the main unit power supply
turned OFF.
OFF
Remarks