Input Data Mode - Daikin LXE10E-A Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
12. OPTIONAL CONDITION SETTING MODE (continued)
S
d2 – –
S
d3 – –
S
S
d – 1 –
S
d – 2 –

13. INPUT DATA MODE

<Key operation to enter/exit>
Power OFF
Circuit Breaker ON
Unit OFF
I/O ON
All indication
lights on
(for 3 sec.)
Starting
preparation
(for 18 sec.)
※ 1
Current
indication
(Operation state)
"d2 – –" message displays the total time in hours, that the temperature was above set point +2°C.
The code will be displayed after the selected time which can be set to: "1"hour, "2"hours, "3"hours,
"4"hours, "5"hours, or "10"hours. When the total time above set point +2°C reaches "1"hour, the
code "d101" will be displayed.
Whenever the
or
the
key to determine the setting.
Refer to page 3-67.
"d3 – –" message displays the total time in hours, that the temperature was above set point +3°C.
The code will be displayed after the selected time which can be set to: "1"hour, "2"hours, "3"hours,
"4"hours, "5"hours, or "10"hours. When the total time above set point +3°C reaches "1"hour, the
code "d101" will be displayed.
Whenever the
or
the
key to determine the setting.
Refer to page 3-67.
"d – 1 –" message displays the total time in hours, that the temperature was below set point -1°C.
The code will be displayed after the selected time which can be set to: "1"hour, "2"hours, "3"hours,
"4"hours, "5"hours, or "10"hours. When the total time below set point -1°C reaches "1"hour, the
code "d101" will be displayed.
Whenever the
or
the
key to determine the setting.
Refer to page 3-67.
"d – 2 –" message displays the total time in hours, that the temperature was below set point -2°C.
The code will be displayed after the selected time which can be set to: "1"hour, "2"hours, "3"hours,
"4"hours, "5"hours, or "10"hours. When the total time below set point -2°C reaches "1"hour, the
code "d101" will be displayed.
Whenever the
or
the
key to determine the setting.
Refer to page 3-67.
(
I/O
I/O OFF
for 3 sec.
for 3 sec.
※ 10
F. PTI
Optional
S. PTI
Function
M. CHECK
Setting
key is pressed, the selection from "1"hour to "10"hours changes. Press
key is pressed, the selection from "1"hour to "10"hours changes. Press
key is pressed, the selection from "1"hour to "10"hours changes. Press
key is pressed, the selection from "1"hour to "10"hours changes. Press
Circuit Breaker OFF
after setting change
OFF when no setting changed)
for 3 sec.
for 3 sec.
※ 11
※ 12
Basic
Optional
Function
Condition
Setting
Setting
3-31
for 3 sec.
※ 13
Input Data