H-Code - Daikin LXE10E-A Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru

3.10.3.2 H-code

H001
=The alarm is displayed when the control temperature does not decrease by 3˚C or more
every 4 hours during pull-down operation.
Inside
Temperature
t
SP+1˚C
SP
H002
=The alarm is displayed when the total time out of "in-range" reaches 2 hours. (Counting is
not performed during defrosting).
SP+1
SP
H003
=The alarm will be displayed when the total time below setpoint –1˚C reaches 2 hours.
H004
=The alarm will be displayed when the total time below setpoint –2˚C reaches 2 hours.
SP
SP–1
SP–2
If "t" is smaller than 3˚C, code "H001" appears.
※ This criteria (3˚C) can be adjusted from 1, 2, 5 or 10˚C.
4Hr
t
1
t
1
t
t
1'
2'
3-65
time
t
+t
+t
> 2Hrs
1
2
3
H002
t
t
2
3
t
+t
> 2Hrs
1
2
t
H003
2
t
'+t
'
> 2Hrs
1
2
H004
Figure2
Figure3