1. INTRODUCTION
1.1 Operation range
Use the units within the following range.
Item
Ambient temperature range
Inside temperature range
Voltage
Vibration and shock
1.2 Basic names of components
1 0
5
9
q Compressor
w Air-cooled condenser
e Receiver
r Evaporator
t Control box
⎛
Outside: switch, manual defrost switch, monitoring
⎜
⎜
receptacle
⎝
Inside: circuit breaker
y Condenser fan
u Drier
-30˚C to +50˚C (-22˚F to + 122˚F)
-30˚C to +30˚C (-22˚F to + 86˚F)
50Hz: 380V/400V/415V, 60Hz: 440V/460V
Voltage fluctuation rate should be within ±10%
8
11
6
1 4
2
1 3
3
7
1
1 2
i Access panel
o Storage space for power cable
!0 Ventilator
!1 Thermometer check port (Return)
※Thermometer check port is not fitted to some models.
⎞
⎟
⎟
⎠
!2 Gas sampling port
Sampling port (Supply)
!3 Liquid moisture indicator
!4 Recorder (optional)
1-1
Operation range
2G
4
⎛
Use this port to measure the
⎝
inside return air temperature.
⎛
This is used to measure the
⎜
inside supply air temperature
⎜
⎝
and inside CO
⎞
⎠
⎞
⎟
⎟
⎠
concentration.
2