Daikin LXE10E-A Service Manual page 125

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
(2-3) Removal of mounting plate
Check the following table to see if the mounting plate should be removed. If the mounting plate must
be removed, remove the four screws and dismount the mounting plate.
Model
Type
Over current setting value
J3
J2
J1
Mounting plate
(3) Replacement procedure
CAUTION
Be sure that the main power is
disconnected.
q Disconnect the wires routed via CT1 and CT2
from the terminals.
※At this time, take care to prevent CT1 and
CT2 from being damaged.
w Disconnect the connector (CN1) for the
controller and the connector (CN2) for the
main circuit.
e Remove four mounting nuts.
r After replacing the PT and CT board, connect
the lead wired in reverse order of the above
removal procedure.
t After checking the wiring once, test-run the
system to verify that no trouble is found.
Over current setting and removal of mounting plate
Spare parts
LXE5C
–––––
Dual 5HP
–––––
8.5A
Not to be
Provided
removed
4-14
LXE10C
LXE10D
Dual 10HP
15A
Not to be
To be
removed
removed
: Cut jumper
: Do not cut jumper
LXE10D
LXE10E
Single 10HP
26A
To be removed

Advertisement

Table of Contents
loading

Table of Contents

Save PDF