11. BASIC FUNCTION SETTING MODE

<Key operation to enter/exit>
Power OFF
Circuit Breaker ON
Unit OFF
I/O ON
All indication
lights on
(for 3 sec.)
for 3 sec.
F. PTI
Starting
S. PTI
preparation
M. CHECK
(for 18 sec.)
※ 1
Current
indication
(Operation state)
<Key operation in this mode>
Whenever the
key is pressed, the display changes.
S
Turn the power breaker OFF after the setting.
CONTROLLER
SETTING
S
LOGGING INTERVAL
SETTING
S
S
DATA RECORDER
SENSOR ON/OFF
SETTING
(
I/O
I/O OFF
for 3 sec.
※ 10
Optional Function
Setting
Select "A", "b" or "c" on the LED while the LCD displays "dECOS-3".
Whenever the
or
key is pressed, the indication of "A" or "b" or "c" is changed.
Press the
key to determine the setting.
"A" represents "DECOS-III a", "b" represents "DECOS-III b" and "c" represents
"DECOS-III c".
The unit is comes with the "DECOS-III c" additionally.
Select "C", and press
To set the logging interval:
Select "15", "30" or "60" on the LED while the LCD displays "LOG INT".
The unit is in minutes.
Whenever the
or
key is pressed, the indication of "15" or "30" or "60" is changed.
Press the
key to determine the setting.
To set the data recorder sensor ON/OFF:
Select "ON" (in use) or "OFF" (not in use) on the LED while the LCD displays
"REC SEN" .
Whenever the
or
changed. Press the
key to determine the setting.
3-27
Circuit Breaker OFF
after setting change
OFF when no setting changed)
for 3 sec.
※ 11
Basic Function
Setting
key to determine the setting.
key is pressed, the indication of "ON" or "OFF" is