Daikin LREQ5B7Y1 Operation Manual

Daikin LREQ5B7Y1 Operation Manual

Air cooled refrigeration condensing unit
Hide thumbs Also See for LREQ5B7Y1:

Advertisement

OPERATION MANUAL
Air cooled refrigeration condensing unit
LREQ5B7Y1
LREQ6B7Y1
LREQ8B7Y1
LREQ10B7Y1
LREQ12B7Y1
LREQ15B7Y1
LREQ20B7Y1

Advertisement

Table of Contents
loading

Summary of Contents for Daikin LREQ5B7Y1

  • Page 1 OPERATION MANUAL Air cooled refrigeration condensing unit LREQ5B7Y1 LREQ6B7Y1 LREQ8B7Y1 LREQ10B7Y1 LREQ12B7Y1 LREQ15B7Y1 LREQ20B7Y1...
  • Page 2: Safety Precautions

    Thank you for purchasing this Daikin condensing unit. Carefully read Consult your dealer for assistance. this operation manual before using the condensing unit. It will tell you The refrigerant used for the condensing unit is safe and normally how to use the unit properly and help you if any trouble occurs.
  • Page 3 Do not use the product in the atmosphere contaminated with Impaired airflow may result in insufficient performance or trouble. oil vapor, such as cooking oil or machine oil vapor. Do not let children play on or around the outdoor unit. Oil vapor may cause crack damage, electric shocks, or fire.
  • Page 4: Name Of Part

    NAME OF PART Indoor unit Defrost 2-1 In the case of LREQ5, LREQ6, LREQ8, Name Freezing control panel LREQ10, LREQ12 Unit cooler Showcase Power supply wires Air outlet (to dedicated earth leakage breaker) Shape For other configuration equipment, refer to the Operation Manuals of the respective pieces of equipment.
  • Page 5: Troubleshooting

    CARE AND CLEANING METHOD 7-2 Check before requesting servicing. 1. The unit does not operate at all. Be sure to stop the operation of the unit with the operation switch • Has the power supply fuse not blown out? and turn off the power (i.e., turn off the earth leakage breaker) Turn off the power.
  • Page 6 PRODUCT MODELS AND MAIN SPECIFICATIONS 9-1 Models and Main Specifications. Model LREQ5 LREQ6 LREQ8 LREQ10 LREQ12 LREQ15 LREQ20 Power supply 3 phase 50 Hz 380~415 V Refrigerant R410A Evaporating temperature –45°C~+10°C Operating condition Outdoor temperature –20°C~+43°C 1,680 × 1,680 × 1,680 ×...
  • Page 7: After-Sale Service

    10. AFTER-SALE SERVICE 10-2 Onerous repairs (Outside scope of warranty coverage) 10-1 After-sale service 10-2-1 Accidents resulting from use beyond standards for use WARNING • Use beyond Limits Consult your local dealer regarding modification, repair and • maintenance of the condensing unit. Applications other than its designed purpose of use or modification.
  • Page 8 10-2-2 Selection, installation, work failures specified below and other failures Note: Asterisk-marked items show concrete examples. 1. Model selection failures • A model not suitable for storage applications is selected. * The cooling of products not reaching the target storage temperatures.
  • Page 12 *4PW74303-1 C 0000000L* 4PW74303-1C 2016.02...