Operation Setting Mode - Daikin LXE10E-A Service Manual

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru

2. OPERATION SETTING MODE

Control temperature, defrosting interval, and control humidity (optional) can be set.
CURRENT (Operation
state) INDICATION MODE
key or non-
S
operation
for 5 minutes
OPERATION SETTING
MODE
Select an item using the
Item
CURRENT INDICATION
MODE
S
CONTROL
TEMPERATURE SETTING
S
S
CONTROL HUMIDITY
SETTING
(optional Note 1)
S
DEFROST
INTERVAL SETTING
Note 1) ●When the humidity control is not set, this indication does not appear.
Note 2) ●In case temperature is set in ˚C setting temperature can be set at interval of 0.1 ˚C.
In case temperature is set in ˚F, setting temperature should be the value converted into ˚F based on
˚C and rounded off the two decimal places.
To change to the OPERATION SETTING MODE, press the
the unit is in the CURRENT INDICATION MODE.
In the OPERATION SETTING MODE, Control temperature, Control
humidity (optional) and Defrosting interval can be set.
key. The value of the selected item is indicated on the LED and LCD display.
S
LED display
Current setting
temperature
Note 2)
Current setting
humidity
Current defrosting
interval
3-10
LED display
"SET-SPC" or "SET-
Change the value using the
SPF"
or
determine the setting.
Setting temperature range; –30 to 30˚C.
"SET-SHU"
Change the value using the
or
determine the setting.
Setting humidity range: 60 to 95%RH
Select a defrost interval 99h, 24h,
"SET-dEF"
12h, 9h, 6h, or 3h using
or
determine the setting.
"On demand defrosting" is
conducted when "99h" has been
selected. (See page 2-23.)
key while
S
Setting method
key
key. Press the
key to
key
key. Press the
key to
key
key. Press the
key to

Advertisement

Table of Contents
loading

Table of Contents