• Easy to install for furniture, decorations and fittings • Daikin remote controls give you easy control at your fingertips. • Can be installed in both new and existing buildings. • The wired remote control provides you with a schedule timer, •...
• Indoor Units • R-410A • FUQ-BVV1B Options FUQ∼B Name of option Remark Sealing member of air discharge outlet KDBH49FA80 KDBH49FA140 Decoration panel for air discharge KDBT49FA80 KDBT49FA140 Vertical flap kit KDGJ49FA80 KDGJ49FA140 Replacement long-life filter KAF495FA140 L connection piping kit KHFP49MA140 Remote control Wired type...
• Indoor Units • R-410A • FUQ-BVV1B Control systems BRC1D52 5 x 10 (Round end slit) 6.5 x 9 (Round end slit) HoleJ5 5 x 7 (Round end slit) Cover closed 3TW23651-2 Cover open • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FUQ-BVV1B Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing unit (mm) FUQ71B Drain connection Drain connection z 1500 mm or location for upper location for rear piping more piping Required space z 1500 mm or more z 1500 mm...
• Indoor Units • R-410A • FUQ-BVV1B Wiring diagram 8 - 1 Wiring diagram FUQ71∼125B In case of simultaneous operation system. To outdoor Notes Indoor unit Indoor unit Wired remote unit (slave) (master) control 1. D : Terminal F : Connector Note) 4 b : Protective earth (screw) : Field wiring...
• Indoor Units • R-410A • FUQ-BVV1B Wiring diagram 8 - 2 External connection diagram FUQ71∼125B V1, Model V3, Model Y1, Model Power supply Power supply Power supply 1∼50Hz 1∼50Hz 3N∼50Hz 220V-240V 230V 400V Main switch Main switch Main switch Fuse Fuse Fuse...
• Indoor Units • R-410A • FUQ-BVV1B Sound data 9 - 2 Sound pressure spectrum FUQ71B FUQ100B H (230V) H (230V) L (230V) L (230V) approximate approximate threshold hearing threshold hearing for continuous for continuous noise noise 4D014037D 4D014038D Octave band center frequency (Hz) Octave band center frequency (Hz) NOTES NOTES...
• Indoor Units • R-410A • FUQ-BVV1B Air flow pattern FUQ71B Cooling - air velocity distribution 4-way discharge air flow direction: horizontal FUQ71B Cooling - air temperature distribution 4-way discharge air flow direction: horizontal 4D028396C • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FUQ-BVV1B Air flow pattern FUQ100B Cooling - air velocity distribution 4-way discharge air flow direction: horizontal FUQ100B Cooling - air temperature distribution 4-way discharge air flow direction: horizontal 4D028397C • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FUQ-BVV1B Air flow pattern FUQ125B Cooling - air velocity distribution 4-way discharge air flow direction: horizontal FUQ125B Cooling - air temperature distribution 4-way discharge air flow direction: horizontal 4D028398C • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FUQ-BVV1B Air flow pattern FUQ71B Heating - air velocity distribution 4-way discharge, air flow direction: down FUQ71B Heating - air temperature distribution 4-way discharge, air flow direction: down 4D013863D • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FUQ-BVV1B Air flow pattern FUQ100B Heating - air velocity distribution 4-way discharge, air flow direction: down FUQ100B Heating - air temperature distribution 4-way discharge, air flow direction: down 4D014054D • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FUQ-BVV1B Air flow pattern FUQ125B Heating - air velocity distribution 4-way discharge, air flow direction: down FUQ125B Heating - air temperature distribution 4-way discharge, air flow direction: down 4D014055D • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FUQ-BVV1B Installation 11 - 1 Installation method Names and functions of parts Indoor unit Outdoor unit Infrared remote control Inlet air Discharged air Air outlet Air flow flap (at air outlet) Refrigerant piping, connection electric wire Drain pipe Air inlet The built-in air filter removes dust and dirt.
Page 22
Daikin Europe N.V. explicitly rejects any liability for any direct Daikin Europe N.V. is approved by LRQA for its Quality Daikin Europe N.V. is participating in the or indirect damage, In the broadest sense, arising from Management System in accordance with the ISO9001 EUROVENT Certification Programme.