5.2 USDA transportation

If USDA receptacles and sensors (Optional) are provided to the unit, the unit can take USDA
transportation. (Refer to arrangement of main component in clause 2.2.2.)

5.2.1 Type of USDA sensor/receptacle

Two types of sensors can be installed, according to the type of receptacles.
User should confirm the type of receptacles and select proper sensor in below table.
According to the model, the quantity of receptacle is different. (3 or 4)
Type
Receptacle
1
T3107003
2
HD10-3-96P
*3 receptacles : USDA 1, USDA 2, USDA 3
4 receptacles : USDA 1, USDA 2, USDA 3, CTS (Cargo temperature sensor)

5.2.2 Initial setting

User should confirm initial setting of controller as below.
1) USDA transportation ; Initial setting mode at page 3-29.
Quantity of receptacles should be set
2) Type of USDA sensor
Type of USDA sensor should be set.

5.2.3 USDA sensor calibration

USDA requires sensor calibration every transportation and report each offset figure. Free-supply
downloading software enable to assist this. Please refer to "Operation manual for Daikin Container
Communication Software".

5.2.4 USDA transportation requirement

Cargo and refrigeration unit shall be required pre-cooling before cargo loading. As to position of USDA
sensors and operation, please refer to the guidance of USDA.

5.2.5 USDA report required by USDA local officer

Free supply downloading software enables you to make document easily, which USDA local officer
requires. In detail, please refer to "Operation manual for Daikin Container Communication Software".
Sensor
ST9702-1
NTC type probe
5-4