8.2.3 Special operation 3 (Applicable models:LXE10E-A11,A20 and A26(A))
1.Name and function of each components
q
w
e
r
o
!0
① SUPPLY LED (Lights when "supply air temperature" is indicated.)
② RETURN LED (Lights when "return air temperature" is indicated.)
③ ALARM LED (Lights alarm is generated.)
④ R.H.LED (Lights when "relative humidity" is indicated.)
⑤ COMP.LED (Lights when the compressor is running.)
⑥ DEFROST LED (Lights when the unit is under the defrosting operation.)
Function of operation key
MODE
M
●MODE Key
Shift from "Current indication mode" G-SET operation." / Automatic pump down mode /
Dehumidication ON-A・OFF setting.
Note: When the dehumidification ON-A ・ OFF is set to ON, G-Set operating mode will be skipped.
t
COMP.
DEFROST INRANGED–HUMID
SUPPLY
RETURN
ALARM
R.H.
1
OVER
SP+5
˚C
2
INRANGE
3
UNDER
S P – 5
˚C
1
HOURS
–12
–10
–8
2
DAYS
–6
–5
–4
DAIKIN ELECTRONICCONTAINER OPERATION SYSTEM
8-22
y
u
i
˚C / ˚F
%R H
–6
–4
–2
–3
–2
–1
DECOS
b
⑦ IN RANGE LED (Lights when the control temperature is in range.)
⑧ DE-HUMID.LED
(Lights when the controller is the
dehumidification control optional.)
⑨ Temperature base (Used for the graphic chart indication
on the LCD.)
⑩ Time base (Used for the graphic chart indication on the LCD.)
※: Dehumidification control is available on A26 and A26A only.